- WR50-1A
50 Amp Winding Resistance Meter
Download WR50-1A PDF
|
|
|
Specifications |
MODEL: WR50-1A
SIZE: L: 521 mm (20.5”) W: 432 mm (17”) H: 216 mm (8.5”)
WEIGHT: 16.8 kg (37 lbs.)
INPUT POWER: 100 to 250 Vac (1.5kW max.), 50/60 Hz, auto ranging
OUTPUT VOLTAGE: 0 to 50V DC
TEST CURRENT: User Selectable: 50, 40, 30, 25, 20, 10, 5A DC
FRONT PANEL: Sealed, Anodized
MEMORY STORAGE: Stores up to 2000 measurement results |
|
|
|
|
|
|
|
|
|
|
|
|
Current Range |
|
Measuring Range |
|
Accuracy |
|
Resolution |
|
50 Amp
40 Amp
30 Amp
25 Amp
20 Amp
10 Amp
5 Amp |
|
0.1 µΩ... 0.6 Ω
0.1 µΩ... 0.9 Ω
0.1 µΩ... 1.6 Ω
0.1 µΩ... 2 Ω
0.1 µΩ... 2.5 Ω
0.1 µΩ... 5 Ω
1 µΩ... 100 Ω |
|
±0.1% Rdg ±2 LSD
±0.1% Rdg ±2 LSD
±0.1% Rdg ±2 LSD
±0.1% Rdg ±2 LSD
±0.1% Rdg ±2 LSD
±0.1% Rdg ±2 LSD
±0.1% Rdg ±2 LSD |
|
5 Digits or 0.1 µΩ
5 Digits or 0.1 µΩ
5 Digits or 0.1 µΩ
5 Digits or 0.1 µΩ
5 Digits or 0.1 µΩ
5 Digits or 0.1 µΩ
5 Digits or 1 µΩ |
|
RESISTANCE RANGE: 0.1 µΩ to 100 Ω
INDUCTANCE RANGE: 0 Henry to 1500 Henry
TEMPERATURE: Operating - 10° C to 60° C Storage - 20° C to 70° C |
|
|
| |
|
- Simple push and turn button operation from Micro Junior
- Charges inductive loads up to 1500 Henry
- Heavy duty protection circuitry
- Fully remote operation and control with an external PC
- 3 Temperature input channels
- High power DC Supply (50A/50V)
- DC Current adjustable for resistance from 0.1 µΩ to 100 Ω
- Data transfer to internal/external printer at selectable intervals
- Fastest discharge unit on the market
- Visible and audible discharge indicator for discharge status
- Emergency discharge activates from emergency stop button or
system power failure
- Data storage of up to 2000 measurements
- Mounted in rugged case for field testing
|
|
- Current and potential lead set 10 meters
- Connection cable to Micro Junior 2 connection cable to Micro Junior 2
- Safety ground lead
- Power supply cord
- Instruction manual
|
|
|
|
- WRO 101 10m current and potential cable extension set
- AHRT 01 Heat-run test software
- TP 01 External temperature probe
|
|
|
| SPECIFICATIONS
ARE SUBJECT TO IMPROVEMENT AT ANY TIME. |
|